Key Features
- DIN-rail Power Adapter
- Output Voltage (DC): 12V; Output Current: 2.5A Max; Rated Power: 30W
- DC Output Voltage Adjustable
- Universal AC input/ Full range
- Protection: Short Circuit/Overload/Over Voltage
- A great partner with an industrial switch
Specifications
| Output | |
|---|---|
| DC Voltage | 12V |
| Rated Current(Max.) | 2.5A |
| Current Range | 0-2.5A |
| Rate Power(Max.) | 30W |
| Ripple & Noise(Max.) | 120mVp-p |
| Volatge ADJ. Range | 10.8-13.8V |
| Voltage Tolerance | 士 2.0% |
| Link Regulation | 士 1% |
| Load Regulation | 士 1% |
| Setup, Rise Time | 500ms, 50ms/230VAC at full load 500ms, 50ms/115VAC at full load |
| Hold Up Time (Typ.) | 30ms/230VAC at full load 12ms/115VAC at full load |
| Input | |
| Voltage Range | 90~264VAC 127~370VDC [DC input by connecting AC/L(+),AC/N(-)] |
| Frequency Range | 47-63Hz |
| Efficiency | 88% |
| AC Current (Typ.) | 0.88A/115VAC 0.48A/230VAC |
| Inrush Current (Typ.) | 25A/115VAC 45A/230VAC |
| Protection | |
| Overload | 105~160% rated output power Hiccup mode when output voltage <50%, recovers automaticallyafter fault condition is removed. Constant current limiting within 50%-100% rated output voltage. Recovers automatically after the fault condition is removed. |
| Over Voltage | 15~18V Protection type : Shut down o/p voltage, re-power on to recover |
| Environment | |
| Working Environment | -20°C~+70°C(Refer to "Derating Curve") ; 20%~95% (Non-condensation) |
| Storage Environment | -40°C~+85°C; 10%~95% (Non-condensation) |
| Other | |
| Product Dimension(W.H.D) | 35*90*58mm |
| Product Weight | 120g |
| Installation | DIN - rail |
| Note 1. All parameters NOT specially mentioned at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple&noise are measured from peak to peak with band width limit of 20MHz(0.1uF and 47uF/50V parallel capacitor under DC output full load,AC nominal input 25 °C ambient temperature). 3. Installation clearances: top with 40mm, bottom with 20mm, left and right with 5mm. increase the space to10-15mm when the adjacent device is heat source. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. Efficiency test after 30 minutes of burn-in. 6. The ambient temperature derating of 3.5°C /1000m for operating altitude higher than 2000m(6500ft). | |